Turbidity Meter, EPA Compliant Portable Kit, Hanna Instruments, HI98703-01

Item: 92-2450-34-EA

UOM: EA (1)
Price:
Sale price$1,299.99

Description

Features:

 

  • High accuracy at low ranges (below 0.05 NTU)
  • Two, three or four point calibration
  • USB and RS232 PC connectivity
  • Log up to 200 records
  • GLP Features
  • User friendly, backlit  display with guidance codes
  • Battery % on startup
  • Continuous current time on display

 

The new HI 98703 portable Turbidity Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for turbidity.  The unit meets and exceeds the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water.  The instrument's EPA compliance reading mode rounds readings to meet EPA reporting requirements.  Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.

Turbidity is measured up to 1000 NTU. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging.  For advanced field operations, the HI 98703 has Fast Tracker™ and can be equipped with HANNA's Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data, up to 200 measurements, can be downloaded to a PC through either USB or RS232 connections using HANNA's optional HI 92000 software.

A two, three or four-point calibration is available using pre-set or user defined standards. Frequent calibration isn't necessary as the system compensates for variations in the intensity of the light source. The instruments' Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instruments is equipped with backlighting. The current date and time can be displayed on the LCD.

 

 

 

Specifications:

 

 
Range
0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection
Automatic
Resolution
0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Accuracy
±2% of reading plus 0.02 NTU
Repeatability
±1% of reading or 0.02 NTU, whichever is greater
Stray Light
< 0.02 NTU
Typical EMC Deviation
±0.05 NTU
Light Detection
Silicon Photocell
Method
Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.
Measuring mode
Normal, Average, Continuous
Turbidity Standards
1, 10, 100 and 750 NTU
Calibration
Two, three or four-point calibration
Light Source
Tungsten filament lamp
Lamp life
Greater than 100,000 readings
Display
60 x 90 mm LCD with back light
Logging Memory
200 records
Serial Interface
USB 1.1 or RS 232
Environment
To 50°C (122°F); max 95% RH non-condensing
Power Supply
(4) 1.5V AA alkaline batteries or AC adapter
Auto Shut-off
After 15 minutes of non-use
Dimensions
224 x 87 x 77 mm (8.8 x 3.4 x 3.0)
Weight
512 g (18 oz.)
 

 Supplied With:
  • HI 98703-01 turbidity meter (115V)
  • Sample cuvettes and caps (5)
  • HI 98703-11 calibration cuvettes
  • HI 93703-58 silicone oil
  • cuvette cleaning cloth
  • batteries
  • AC adapter
  • instruction manual
  • rugged carrying case
  • Instrument Quality Certificate
  • HI 92000 tag holders and tags (5)
 
 